Peristaltic Pumps for Prevention of 'Intersex' Fish
Peristaltic technology aids in prevention of 'feminised' male fish
However, its tendency to release gas bubbles and cause gas locking at the valves poses a major challenge to conventional pumping techniques. South East Water has overcome this difficulty by opting for peristaltic pumping technology from Watson-Marlow Bredel.
Peristaltic technology provides the ideal solution for pumping sodium hypochlorite.
Sodium hypochlorite is a corrosive chemical that has disinfection and bleaching properties, and is used in the purification of wastewater and the disinfection of drinking water. However, dealing with the chemical can be difficult as it is toxic and emits chlorine when in contact with acids. It naturally releases tiny bubbles of gas, which have a tendency to collect on the small ball valves found in conventional diaphragm dosing pumps. This can cause gas locks in the system, which prevent the pumps from functioning.
South East Water had been using such diaphragm pumps to dose sodium hypochlorite into drinking water. However, they found that the formation of gas locking problems necessitated maintenance on a regular basis. When the pumps were replaced with 520U/R IP66 peristaltic pumps supplied by Watson-Marlow Bredel, this problem was eliminated.
Peristaltic pumps have no valves, seals or glands and the fluid only contacts the bore of the elastomeric hose or tube.
Peristaltic pumps operate by drawing fluid into a tube and pushing it through by the movement of a series of rollers. These rollers alternately compress and release the tube, and, unlike the system of a diaphragm pump, there are no valves in thedosing head. South East Water found that the gas produced by sodium hypochlorite was able to pass straight through the tube without interrupting the dosing process, thereby reducing maintenance on the sodium hypochlorite pumps dramatically.
“We’ve worked with Watson-Marlow for years,’ explained Ray Lawrence, Process Engineer at South East Water, ‘so we understood the value of their peristaltic technology, and decided to use it in an innovative way. Because peristaltic pumps retain the fluid completely within the tube and have no valves that canmay leak or corrode, they can be used for the accurate metering of substances as challenging as sodium hypochlorite, without the associated gas locking and maintenance problems. Peristaltic technology has helped us to keep costly downtime to a minimum. ”
South East Water is also using the pumps for dosing sodium bisulphite, in order to de-chlorinate the water after disinfection to remove the unpleasant taste. The chemical is dosed in very small quantities, which requires a high degree of precision and accuracy from the pump. Previously, it had been necessary to dilute the sodium bisulphite in order to control the dosage procedure accurately. This added an extra degree of complexity to the process, but Watson-Marlow’s 520U/R IP66 peristaltic pump technology resolved the issue. The pump can be calibrated either by weight or volume, allowing very precise dosing and metering. South East Water is now able to dose small amounts reliably even at low pressure, without the need for dilution.